Home > Products > MV Power Cables

N2XSEY NA2XSEY N2XSE2Y NA2XSE2Y Three Cores Cable are
N2XSEY NA2XSEY N2XSE2Y NA2XSE2Y Three Cores Cable are

N2XSEY NA2XSEY N2XSE2Y NA2XSE2Y Three Cores Cable are

Three-core cables N2XSEY & NA2XSEY – safe and reliable.
XLPE insulated, copper or aluminum core, PVC sheathed.
Ideal for power distribution up to 36 kV.
IEC/VDE standard 3-core cables for industrial installations.
Durable armoured MV cables – N2XSEY / NA2XSE2Y available.

Application

 

N2XSEY, NA2XSEY, N2XSE2Y, and NA2XSE2Y are three-core medium voltage power cables designed for fixed installation in power distribution systems up to 12/20(24) kV or 18/30(36) kV. These cables are manufactured in accordance with DIN VDE 0276-620 / IEC 60502-2, ensuring high reliability and safety.

 

These cables feature copper (N2X…) or aluminum (NA2X…) conductors, XLPE insulation, and a copper wire screen with copper tape for effective electromagnetic shielding and fault current return paths. The difference between SEY and SE2Y lies in the outer sheath:

 

  • SEY uses PVC (Polyvinyl Chloride)
  • SE2Y uses PE (Polyethylene) for enhanced moisture resistance and mechanical durability.

These cables are UV-resistant, flame-retardant, and suitable for direct burial or installation in ducts, making them ideal for infrastructure, industrial plants, and utility distribution networks.

 

With continuous operation at 90°C, short-circuit tolerance up to 250°C, and high dielectric strength, these cables offer long service life, low capacitance, and reliable performance under tough environmental and electrical conditions.

 

Specifications

 

Aspect Details & Applications
Cable Type N2XSEY / N2XSE2Y: Copper conductorNA2XSEY / NA2XSE2Y: Aluminum conductor
Number of Cores 3 cores – individually insulated and laid up together
Conductor Class Class 2 (stranded), per IEC 60228
Insulation Material Cross-linked polyethylene (XLPE) – high thermal and electrical performance
Inner Sheath Extruded PE (polyethylene) layer or thermoplastic bedding
Screen Individual copper wire + copper tape screen per core (for electromagnetic shielding and fault path)
Armour None (unarmoured)
Outer Sheath Black PE (polyethylene) or optionally PVC – UV, weather, and moisture resistant
Rated Voltage Typically 6/10 kV, 12/20 kV, or 18/30 kV
Operating Temperature Continuous: 90°C; Short-circuit: up to 250°C
Standards IEC 60502-2, VDE 0276-620, HD 620 S2
Flame Retardance Flame-retardant according to IEC 60332-1; LSZH versions available
Typical Applications – Medium voltage power distribution in utility, industrial, and infrastructure networks– Suitable for underground installation, cable ducts, or outdoor use without mechanical protection
Naming Note “2Y” indicates double-layer PE sheath, offering enhanced mechanical & environmental protection

STANDARD

 

IEC 60502-2

VDE 0276-620

HD 620 S2

6-10KV Medium Voltage Three Cor
Nom
nsulation hickness
Copper tape
thickness
Copper wire
screen area
Appro.Insulation dia Nom
armor
thickness
Nom
sheath thickness
Appro
overall
diameter
Appro weight
(kg/km)
 
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) CU AL
25 6.05 3.4 0.1 16 12.5 0.5 2.3 44 3200 2700
35 7.1 3.4 0.1 16 13.5 0.5 2.4 46 3700 2000
50 8.25 3.4 0.1 16 14.7 0.5 2.5 49 4300 3400
70 9.9 3.4 0.1 16 16.3 0.5 2.6 53 5200 3900
95 11.7 3.4 0.1 16 18.1 0.5 2.8 57 6400 4600
120 13.1 3.4 0.1 16 19.5 0.5 2.9 61 7400 5200
150 14.3 3.4 0.1 25 20.7 0.5 3 64 8500 5700
185 16.3 3.4 0.1 25 22.7 0.5 3.1 68 10000 6500
240 18.7 3.4 0.1 25 25.3 0.5 3.3 74 12300 7600
300 20.9 3.4 0.1 25 27.9 0.5 3.4 79 14600 8800
400 23.7 3.4 0.1 35 31.1 0.8 3.7 87 18700 11300

 

Construction data 2XSE2Y/N2XSE2Y,A2XSE2Y/NA2XSE2Y 6/10; 12/20; 18/30 kV
Number of
conductors and nominal cross section
Thickness of insulation Thickness
of
sheath
Nominal cross section of
screen
Cable diameter approx. 2XSE2Y,
N2XSE2Y
A2XSE2Y,
NA2XSE2Y
Mass of
Cu approx.
Mass of
cable
approx.
Mass of
Al approx.
Mass of
cable
approx.
Nxmm2 mm mm mm2 mm kg/km kg/km kg/km kg/km
6/10 kV
3×35mm/16
3×50mm/16
3,4
3,4
2,5
2,5
16
16
46,4
48,8
1010 1363 2849
3348
298
404
2174
2437
3×70m/16 3,4 2,7 16 53,0 1968 4208 584 2894
3×95mm/16 3,4 2,8 16 57,1 2732 5229 809 3402
3×120mm/16 3,4 2,9 16 60,3 3440 6108 1023 3812
3x150rm/25 3,4 3,0 25 64,2 4245 7287 1257 4449
3×185mm/253×240rm/25 3,4
3,4
3,2
3,4
25
25
68,5
74,3
5311 6981 8632
10690
1579
2071
5086
6027
3×300mm/25 3,4 3,5 25 79,6 8661 12766 2589 6999
12/20 kV
3×35mm/16 5,5 2,8 16 56,7 1010 3714 298 3038
3×50mm/16
3×70mm/16
5,5
5,5
2,9
3,0
16
16
59,3
63,3
13631968 4259
5153
404
584
3349
3839
3×95rm/16
3×120mm/16
5,5
5,5
3,1
3,2
16
16
67,4
70,6
2732 3440 6226
7162
809
1023
4399
4866
3x150rm/25 5,5 3,4 25 74,7 4245 8439 1257 5601
3×185rm/25 5,5 3,5 25 78,8 5311 9830 1579 6284
3×240mm/25 5,5 3,7 25 84,5 6981 11998 2071 7334
18/30 kV
3×50mm/16 8,0 3,3 16 71,7 1363 5505 404 4596
3×70m/16 8,0 3,4 16 75,8 1968 6480 584 5167
3×95mm/16 8,0 3,5 16 79,8 2732 7651 809 5824
3×120m/16 8,0 3,7 16 83,3 3440 8665 1023 6369
3x150rm/25 8,0 3,8 25 87,1 4245 10019 1257 7181

 

get in touch

Huili Cable Co., Ltd. (formerly Luohe Huili Cable Co., Ltd. and Luohe Cable Factory) was founded in 1989 and was renamed Huili Cable Co., Ltd. on September 14, 2024. The company's registered capital is RMB 200 million.