Home > Products > Aerial Bundled Cable

MV ABC Cable SAC Cable( ICEA S-66-524)
MV ABC Cable SAC Cable( ICEA S-66-524)

MV ABC Cable SAC Cable( ICEA S-66-524)

This standard applies of supported spacer cable. These conductors are intended primarily for the distribution of electrical energy under normal conditions of overhead (aerial) installations.

APPLICATION

This standard applies of supported spacer cable. These conductors are intended primarily for the distribution of electrical energy under normal conditions of overhead (aerial) installations. They are considered as covered conductors therefore the cables carry no voltage rating. The conductors must be installed on insulators and/or spacers adequate for the service voltage. The user may want to give consideration to the dielectric compatibility of the covering, insulator, spacer.

CONSTRUCTION

tree wire

• Conductor: Stranded, circular compressed aluminum.
• Conductor Screen: The extruded Semi-conducting conductor shield in Black.
• Inner Insulation: Natural color thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE).
• Outer Insulation: Thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE) in Black or Grey with Weather or UV resistant.

CHARACTERISTICS

Ⅰ. Electrical Performance

SAC aerial cable adopts high-precision compacted aluminum conductor and complete semiconductive shielding together with XLPE insulation system, which ensures low electrical resistance, stable dielectric strength and high insulation resistance during long-term operation.

Ⅱ. Thermal Performance

The cable supports stable long-term operating temperature of 90°C for XLPE insulation type, tolerates 130°C under continuous overload conditions and withstands 250°C instantaneous short-circuit temperature, providing reliable thermal stability for variable power load operation.

Ⅲ. Weather and Aging Resistance

Formulated with weather-resistant polymer sheath, the cable possesses excellent ultraviolet resistance, oxidation resistance and waterproof performance, resisting long-term outdoor exposure, sunlight aging and harsh atmospheric erosion.

Ⅳ. Anti-Tracking and Pollution Resistance

The outer insulation layer adopts special anti-tracking formula, which effectively prevents surface creepage, tracking discharge and insulation degradation caused by dust, moisture and environmental contamination.

Ⅴ. Mechanical Performance

With compact stranded conductor and seamless extruded insulation structure, the cable features good tensile strength, compression resistance and flexible bending property to adapt to aerial tension stringing and complex field installation.

Ⅵ. Operational Safety and Adaptability

The fully insulated design effectively avoids short-circuit faults caused by tree branch contact and foreign object collision, greatly improving the operational safety of overhead distribution lines and reducing line failure rate.

 

STANDARD

ICEA S-66-524

IEC 60502-2

GB/T 14049

 

SAC Cable (AAC/XLPE/XLPE)                                                     IEC 60502-2;ICEA S  66-524                                  
Nominal Size Min. No.
of Wires
Covering Thickness Cable Diameter Min. Breaking Load Weight
Conductor Shield Inner Layer Outer Layer
mm2 No. mm mm mm mm N kg/km
3-Layer 15kV AAC/XLPE/XLPE
25 6 0.60  1.91 1.91 15.2  3762 218
35 6 0.60  1.91 1.91 16.2  5177 258
50 6 0.60  1.91 1.91 17.3  7011 307
70 12 0.60  1.91 1.91 19.0  10354 387
95 15 0.60  1.91 1.91 20.8  13727 482
120 15 0.60  1.91 1.91 22.0  17339 564
150 15 0.60  1.91 1.91 23.7  21033 660
185 30 0.60  1.91 1.91 25.3  26732 780
240 30 0.60  1.91 1.91 27.6  34679 968
3-Layer 25kV AAC/XLPE/XLPE
25 6 0.70  3.18 3.18 20.1 3762 351
35 6 0.70  3.18 3.18 21.1 5177 398
50 6 0.70  3.18 3.18 22.2 7011 455
70 12 0.70  3.18 3.18 23.9 10354 548
95 15 0.70  3.18 3.18 25.7 13727 657
120 15 0.70  3.18 3.18 26.9 17339 748
150 15 0.70  3.18 3.18 28.6 21033 856
185 30 0.70  3.18 3.18 30.2 26732 989
240 30 0.70  3.18 3.18 32.5 34679 1195
3-Layer 35kV AAC/XLPE/XLPE
25 6 0.70  4.45 3.18 22.6 3762 433
35 6 0.70  4.45 3.18 23.6 5177 485
50 6 0.70  4.45 3.18 24.7 7011 545
70 12 0.70  4.45 3.18 26.4 10354 645
95 15 0.70  4.45 3.18 28.2 13727 761
120 15 0.70  4.45 3.18 29.4 17339 856
150 15 0.70  4.45 3.18 31.1 21033 971
185 30 0.70  4.45 3.18 32.7 26732 1110
240 30 0.70  4.45 3.18 35.0  34679 1324
SAC Cable (AAC/XLPE/HDPE)                                                     IEC 60502-2;ICEA S 66-524                                  
Nominal Size Min. No.
of Wires
Covering Thickness Cable Diameter Min. Breaking Load Weight
Conductor Shield Inner Layer Outer Layer
mm2 No. mm mm mm mm N kg/km
3-Layer 15kV AAC/XLPE/HDPE
25 6 0.60  1.91 1.91 15.2  3762 221
35 6 0.60  1.91 1.91 16.2  5177 261
50 6 0.60  1.91 1.91 17.3  7011 310
70 12 0.60  1.91 1.91 19.0  10354 390
95 15 0.60  1.91 1.91 20.8  13727 486
120 15 0.60  1.91 1.91 22.0  17339 568
150 15 0.60  1.91 1.91 23.7  21033 664
185 30 0.60  1.91 1.91 25.3  26732 785
240 30 0.60  1.91 1.91 27.6  34679 973
3-Layer 25kV AAC/XLPE/HDPE
25 6 0.70  3.18 3.18 20.1 3762 356
35 6 0.70  3.18 3.18 21.1 5177 404
50 6 0.70  3.18 3.18 22.2 7011 461
70 12 0.70  3.18 3.18 23.9 10354 555
95 15 0.70  3.18 3.18 25.7 13727 664
120 15 0.70  3.18 3.18 26.9 17339 755
150 15 0.70  3.18 3.18 28.6 21033 864
185 30 0.70  3.18 3.18 30.2 26732 997
240 30 0.70  3.18 3.18 32.5 34679 1203
3-Layer 35kV AAC/XLPE/HDPE
25 6 0.70  4.45 3.18 22.6 3762 439
35 6 0.70  4.45 3.18 23.6 5177 491
50 6 0.70  4.45 3.18 24.7 7011 552
70 12 0.70  4.45 3.18 26.4 10354 652
95 15 0.70  4.45 3.18 28.2 13727 768
120 15 0.70  4.45 3.18 29.4 17339 864
150 15 0.70  4.45 3.18 31.1 21033 980
185 30 0.70  4.45 3.18 32.7 26732 1119
240 30 0.70  4.45 3.18 35.0  34679 1334

get in touch

Huili Cable Co., Ltd. (formerly Luohe Huili Cable Co., Ltd. and Luohe Cable Factory) was founded in 1989 and was renamed Huili Cable Co., Ltd. on September 14, 2024. The company's registered capital is RMB 200 million.

    Home WhatsApp Mail Inquiry