Home > Products > Armoured Cable

Direct Buried Or ConduitFiber Optic cable - GYFTA53
Direct Buried Or ConduitFiber Optic cable - GYFTA53

Direct Buried Or ConduitFiber Optic cable - GYFTA53

Outdoor Direct-Buried Optical Cable with Non-Metallic Reinforcement, Water-Blocking Filler, Aluminum-Plastic Composite Tape Moisture-Proof, and Steel Tape Armored Double Sheath

APPLICATION

Spiral Steel Tube Armored Cable Vibration is designed for micro vibration design of a sensor cable, optical fiber sensing system with double layer stainless steel sheathed sheath protection, high performance of tensile, compressive, torsional, rat bite, cutting, waterproof, soft tenacity and other characteristics, suitable for all kinds of bad environment.

CONSTRUCTION

GYFTA53-ANATOMY-1

 

• Central Steength Core

• Loose Tube

• Optic Fiber

• Aluminum Tape

• Inner Sheath PE/LSZH

• Steel Tape Armored

• Outer Sheath PE/LSZH 

CHARACTERISTICS

GYFTA53 Outdoor Direct-Buried Optical Cable - Non-metallic Reinforcement, Water-Blocking Filler, Aluminum-Plastic Composite Tape Moisture-Proof, Steel Tape Armored Double Sheath
I. Structural Characteristics

1. Central loose tube stranded structure, optical fiber placed in PBT loose tube, filled with fiber grease to isolate moisture;

2. Cable core gaps are fully filled with water-blocking grease, providing longitudinal water blocking;

3. Central load-bearing component is an FRP non-metallic reinforcing core, without a steel core, and the entire cable contains no conductive metal;

4. Cable core is longitudinally wrapped with aluminum-plastic composite tape (A layer) to achieve radial moisture protection and moisture isolation;

5. Inner polyethylene sheath → corrugated steel tape longitudinal armor (compression-resistant and rodent-resistant) → outer black HDPE sheath, three-layer protection (aluminum-plastic layer + steel tape armor + outer sheath).

II. Optical Transmission Characteristics

1. Mainstream uses G.652D single-mode fiber, with low attenuation and low dispersion, suitable for Gigabit/10 Gigabit, PTN, OTN, security monitoring, government and enterprise dedicated lines, and 5G transport;

2. Completely free of metallic conductors, zero electromagnetic induction, resistant to strong electromagnetic interference, unaffected by power frequency and lightning electromagnetic pulses when laid near high-voltage lines, substations, and electrified railways;

3. No electromagnetic radiation, will not interfere with surrounding weak current and power equipment;

4. Fiber core count coverage of 4/6/12/24/48/72/96/144 cores, meeting the needs of high-capacity transmission in multiple scenarios for backbone and branch lines.

III. Electrical Safety Characteristics (Core Advantages)

1. All-non-metallic structure, containing no steel wire, steel strand, or metallic conductive core, insulated and non-conductive;

2. No induced voltage in high-voltage environments, will not introduce high-voltage potential during lightning strikes, ensuring high personal safety during construction and maintenance;

3. No metallic loops, no power frequency circulating current, no corrosion or electrochemical reactions, suitable for direct burial in areas with strong electromagnetic fields.

IV. Mechanical Properties

1. Corrugated steel tape armor (53 armor): Extremely strong resistance to pressure, lateral pressure, and impact; withstands crushing from gravel and mechanical excavation forces during direct burial.

2. Steel tape is rodent-proof and termite-proof, significantly reducing the probability of damage to buried optical cables.

3. The steel tape armor layer has a certain resistance to trampling and heavy object crushing, superior to unarmored GYFTY and GYFTA optical cables.

V. Environmental and Weather Protection Characteristics

1. Dual moisture-proof system: Loose tube fiber grease + cable core water-blocking grease achieves complete longitudinal water blocking; APL aluminum-plastic composite tape isolates groundwater and prevents radial moisture penetration, providing excellent waterproof performance.

2. Double-layer PE outer sheath is UV-resistant and aging-resistant, protecting underground buried cables from direct sunlight, while also resisting soil acid and alkali corrosion and groundwater corrosion.

3. Operating temperature range: Laying temperature -10℃~+50℃, long-term operation temperature -40℃~+70℃; suitable for direct burial in frozen soil and high-temperature areas in both northern and southern regions.

STANDARD

YD/T 1258.4-2005

ICEA-596

GR-409

IEC 332-1 

IEC 332-3C

Fiber
count
Structure Fibers
per tube
Loose tube
diameter
(mm)
CSM
diameter
/pad
diameter
(mm)
Nominal
Thickness
of outer
jacket
(mm)
Cable diameter
/Height
(mm)
Cable
weight
(kg/km)
Tensile resistance
Long/short term
N
Crush resistance
Long/short term
N/100m
4 1+6 4 2.0±0.1 2.0/2.0 1.75 9.5±0.3 65 1500/4000 300/1000
6 1+6 6 2.0±0.1 2.0/2.0 1.9 9.8±0.3 70 1500/4000 300/1000
8 1+6 8 2.0±0.1 2.0/2.0 1.9 9.8±0.3 70 1500/4000 300/1000
12 1+6 6 2.0±0.1 2.0/2.0 1.9 9.8±0.3 70 1500/4000 300/1000
24 1+6 6 2.0±0.1 2.0/2.0 1.9 9.8±0.3 70 1500/4000 300/1000
36 1+6 12 2.1±0.1 2.2/2.2 1.9 10.2±0.3 82 1500/4000 300/1000
48 1+6 12 2.1±0.1 2.2/2.2 1.9 10.2±0.3 82 1500/4000 300/1000
60 1+6 12 2.1±0.1 2.2/2.2 1.9 10.2±0.3 85 1500/4000 300/1000
72 1+6 12 2.1±0.1 2.2/2.2 1.9 10.2±0.3 88 1500/4000 300/1000
96 1+8 12 2.1±0.1 2.2/3.6 2 12.0±0.3 110 1500/4000 300/1000
144 1+12 12 2.1±0.1 2.4/6.3 2 14.5±0.3 155 1500/4000 300/1000
216 1+6+12 12 2.1±0.1 2.2/2.2 2.05 14.7±0.3 165 1500/4000 300/1000
288 1+9+15 12 2.1±0.1 2.2/4.0 2.05 16.5±0.3 220 1500/4000 300/1000
Characteristics Specified Values Units
Optical Characteristics
Mode field diameter at 1310nm 9.2±0.5 µm
at 1550nm 10.3 ±0.7 mm
Attenuation coefficient at 1310nm ≤0.32 dB/km
at 1550nm ≤0.22 dB/km
Attenuation non-uniformity ≤0.05 dB
Zero dispersion wavelength ( λ0) 1300 ~1324 nm
Max zero dispersion slope (S0max) ≤0.092 ps/(nm2·km)
Polarization mode dispersion coefficient(PMDQ) ≤0.2
Cut-off wavelength (λcc) ≤1260 nm
Dispersion coefficient 1288~1339nm ≤3.5 ps/(nm·km)
1550nm ≤18 ps/(nm·km)
Geometric characteristic
Cladding diameter 125.0±1.0 µm
Cladding non-circularity ≤1.0 %
Coating diameter 245.0±10.0 µm
Coating-cladding concentricity error ≤12.0 µm
Coating non-circularity ≤6.0 %
Core-cladding concentricity error ≤0.8 µm
Mechanical characteristic
Curling ≥4 m
Proof stress ≥0.69 GPa
Coating strip force Average value           1.0-5.0 N
Peak value 1.3-8.9 N
Macro bending loss Ф60mm, 100 circles, at 1550nm ≤0.05 dB
Ф32mm, 1 circles, at 1550nm ≤0.05 dB

get in touch

Huili Cable Co., Ltd. (formerly Luohe Huili Cable Co., Ltd. and Luohe Cable Factory) was founded in 1989 and was renamed Huili Cable Co., Ltd. on September 14, 2024. The company's registered capital is RMB 200 million.

    Home WhatsApp Mail Inquiry